About 30,600 results
Open links in new tab
  1. S-1 & S-2 Regarding Parking Garage - The Building Code Forum

    Jan 7, 2015 · Because this garage is over 1,000 SF it falls outside the scope of a "private garage" and is, for code purposes, a "public garage". Section 311.3 Classifies "Parking garages, open …

  2. Equipment Bollard in a Residential Garage - The Building Code …

    Oct 20, 2009 · Re: Equipment Bollard in a Residential Garage We have a minimum 36 inch high 2" schedule 40 iron pipe embedded in the garage slab. We also have two alternates that are …

  3. Garage pedestrian door size | The Building Code Forum

    Nov 24, 2025 · I have a single car garage with a sectional overhead door, I have space on one stucco wall for a 24 x 75 pedestrian door. will that size be acceptable since it is not the main …

  4. Minimum Floor Slope for Drainage - The Building Code Forum

    Oct 19, 2009 · Irc The building code requires that a garage floor be sloped towards the door, but does not specify a minimum slope. It is usually 1/8” to 1/4” per foot. Here is the citation from …

  5. HVAC in a garage - The Building Code Forum

    Jan 12, 2012 · Codes do not permit duct openings in a residential attached garage, for obvious reasons. I ran across one yesterday where it appears that the contractor is placing an air …

  6. Egress through a garage. | The Building Code Forum

    Apr 9, 2015 · A detached garage is not going to require egress in the same manner as a habitable space. How do you egress out of a garage itself?

  7. Step from garage into House?? - The Building Code Forum

    Jul 22, 2019 · I do not see anywhere in the IRC 2015 that requires a step from the garage into the house. I saw the opening penetrations R302.5 & Garage section R309. Is the step still a …

  8. 2024 Portal Frames - The Building Code Forum

    Apr 1, 2024 · In the picture provided, I would say that is still a single portal frame opening. I think the intent was to prevent two portal frames immediately adjacent to each other using a …

  9. Branch Circuit to Detached Garage - The Building Code Forum

    Oct 16, 2009 · An electrical service disconnect is located in or on the main structure. One of the panelboard has a 20A GFCI breaker that is labeled "garage." The garage is detached and the …

  10. Exit Access Stair in Open Parking Garage - Exit Discharge

    Nov 9, 2020 · Typically an exit access stair is locate inboard with the exit travel distance continuing beyond the stair to the exit door, but not in this case due to the open parking …